Flow | 0.5 cc/min to 4 liters/min; 0 to 1.05 gpm |
Port Size | 1/8″ NPT or #4 SAE or Manifold Mount |
Accuracy | (at 30 cP): ± 0.3% of reading over a 100:1 range |
Pressure | 6000 psi (414 bar) maximum |
K-Factor | 500 pulses/cc |
Fluids | Most non aqueous, hydrocarbon based liquids |
G004 Gear Flow Meter
If you value your flow, find value in the data from a Max Gear Meter. From heavy duty hydraulics to adhesive dispensing, Max Gear Meters provide more data per liter of fluid to give you more control of your flow.
Choose from frequency or analog transmitter options. High temperature models up to 225°C available. CE Certified, Ex-proof version available with ATEX/IECEx and UL/cUL certifications.
Specifications
MECHANICAL
Filtration
|
10 Micron recommended
|
Weight
|
1.1 kg (2.42 lbs)
|
MATERIALS OF CONSTRUCTION
External
|
Stainless steel, type 303; Fluoropolymer coated bolts; MoS2 lubricant
|
Wetted
|
Stainless steel, type 303, 440C, 17-4;
Nickel plated SmCo magnet
|
O-Rings
|
Standard: Viton®
Optional: Teflon®, Perfluoroelastomer |
TRANSMITTER VARIATIONS
Signal Type
|
Output
|
Resolution (K-Factor)
|
Std. Temp†
|
High Temp†
|
Ultra Temp
|
---|---|---|---|---|---|
Frequency
|
5 VDC square wave (current sinking available)
|
500 pulses/cc
|
90°C
|
155°C
|
225°C
|
Frequency
|
5 VDC quadrature (2-phase)
|
250 pulses/cc/phase
|
90°C
|
155°C
|
225°C
|
Analog
|
0-10 VDC
|
Uni or Bi-directional
|
90°C
|
155°C
|
225°C
|
Analog
|
4-20 mA
|
Uni or Bi-directional
|
90°C
|
155°C
|
225°C
|
Compliance:
|
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx.†Maximum temperature rating for ATEX certified transmitters is 75°C Std. Temp and 130°C High Temp.
|
Applications
-
Diesel Exhaust Fluid (AdBlue) Measurement
Diesel Exhaust Fluid (AdBlue®) System Flow Measurement. Selective Catalytic Reduction (SCR) revolves around the use of…
-
Flow Meters for Measuring Brake Fluid In-line
Brake Fluid In-Line Flow Testing. Flow measurement is used for mapping flow profiles, testing for system…
-
Hydraulic Valve, Pump, and Cylinder Testing
Testing of hydraulic valves, pumps and cylinders covers a wide range of flows. From full flow…
-
Precise Defoamer Ratio Control
Aqueous and Non-aqueous antifoaming and defoaming solutions and dispersants are used in a variety of processes…
-
Hot Melt Adhesive Dispensing Applications Measured to a Fraction of a Gram
Quality and performance can change with a small amount of material in thermoplastic and reactive hotmelt…
Downloads
GEAR FLOW METERS | MANUAL | ANALOG SPEC SHEET | FREQUENCY SPEC SHEET | PN SELECTOR | CALIBRATION EXAMPLE |
---|---|---|---|---|---|
G004 Gear Flow Meter
|
Drawings / Charts
Related STEP Files
-
Gear Meter STEP Files
G004-INDUSTRIAL-225C-TEMP-RATING-WITH-HEAT-TRACE- STEP File
Free Download Add to cart