Flow | 250 cc/min to 240 liters/min; 0.07 to 63.4 gpm |
Port Size | 1″ NPT or #16 SAE |
Accuracy | (at 30 cP): ± 0.3% of reading over a 100:1 range |
Pressure | 4000 psi (275bar) – NPT fittings 6000 psi (414 bar) – SAE fittings maximum |
K-Factor | 7,000 pulses/L |
Fluids | Most non aqueous, hydrocarbon based liquids |
Gear Flow Meters
G240 Gear Flow Meter
If you value your flow, find value in the data from a Max Gear Meter. From heavy duty hydraulics to adhesive dispensing, Max Gear Meters provide more data per liter of fluid to give you more control of your flow.
Choose from frequency or analog transmitter options. High temperature models up to 225°C available. CE Certified, Ex-proof version available with ATEX/IECEx and UL/cUL certifications.
Specifications
MECHANICAL
Filtration
|
30 Micron recommended
|
Weight
|
21 kg (46.0 lbs)
|
MATERIALS OF CONSTRUCTION
External
|
Stainless steel, type 303;
Xylan Coated Bolts
|
Wetted
|
Stainless steel, type 303, 440C, 17-4;
Nickel plated SmCo magnet
|
O-Rings
|
Standard: Viton®
Optional: Teflon®, Perfluoroelastomer |
TRANSMITTER VARIATIONS
Signal Type
|
Output
|
Resolution (K-Factor)
|
Std. Temp†
|
High Temp†
|
Ultra Temp
|
---|---|---|---|---|---|
Frequency
|
5 VDC square wave (current sinking available)
|
7000 pulses/L
|
90°C
|
155°C
|
225°C
|
Frequency
|
5 VDC quadrature (2-phase)
|
3,500 pulses/L/phase
|
90°C
|
155°C
|
225°C
|
Analog
|
0-10 VDC
|
Uni or Bi-directional
|
90°C
|
155°C
|
225°C
|
Analog
|
4-20 mA
|
Uni or Bi-directional
|
90°C
|
155°C
|
225°C
|
Compliance:
|
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx.†Maximum temperature rating for ATEX certified transmitters is 75°C Std. Temp and 130°C High Temp.
|
Applications
-
Precise Polyurethane Ratio Control
Polyol and isocyanate blending applications for cast elastomers, and rigid or flexible foam applications such as…
-
Precise Defoamer Ratio Control
Aqueous and Non-aqueous antifoaming and defoaming solutions and dispersants are used in a variety of processes…
-
Hydraulic Valve, Pump, and Cylinder Testing
Testing of hydraulic valves, pumps and cylinders covers a wide range of flows. From full flow…