370 Series Vapor Eliminator and Level Controller

Flow up to 5250 cc/min
Port Sizes 1/4″ and 3/8″ NPT
Pressure up to 100 psi maximum
Fluids Diesel, gasoline, ethanol, and other hydrocarbon based fuels
Category:
MATERIALS OF CONSTRUCTION
370/372 Vapor Eliminators and Level Controllers
Body
Stainless steel, type 303
Valve Orifice
Stainless steel, type 303
Valve Seal
Nitrile
Float, Stem, Levers, Screen
Stainless steel, type 304
MECHANICAL
370 Vapor Eliminator
Data
All
Gasoline
Ethanol
Diesel
Volume
202.1 cc
Supply Line Size
1/4” or 3/8” tubing
Maximum Operating Pressure
100 psi
Maximum Inlet Flow rate
(liquid plus entrained gases)*
5250
cc/min
4375
cc/min
3500
cc/min
Maximum Temperature of Fuel
130°F
140°F
200°F
* NOTE: Flow rates approaching the maximum of the Inlet Port will reduce the vapor elimination capabilities
370 Level Controller
Data
All
Gasoline
Ethanol
Diesel
Volume (w/10 psi supply)
202.1 cc
Maximum Inlet Fuel Pressure
20 psi
Maximum Fuel Flow Rate
Inlet Port (no vapor)*
2200
cc/min
2000
cc/min
1500
cc/min
Maximum Fuel Flow Rate
Return Port (< 1000 cc/minute vapor)*
3000
cc/min
2500
cc/min
2000
cc/min
Maximum Temperature of Fuel
130°F
140°F
200°F
*NOTE: Flow rates approaching the maximum of either the Inlet Port or the Return Port will reduce the vapor elimination capabilities.
372 Vapor Eliminator and Level Controller
Data
All
Gasoline
Ethanol
Diesel
Max Float Bowl Pressure
75 psi
Max Air Eliminator
Rate @500 cc/min
2100
cc/min or better
2100
cc/min or better
2100
cc/min
Max Air Eliminator
Rate @1000 cc/min
1500
cc/min or better
1500
cc/min or better
1500
cc/min
Max Air Eliminator
Rate @2000 cc/min
300
cc/min or better
300
cc/min or better
300
cc/min
Level Controller Max Return Rate
2000
cc/min
Maximum Temperature of Fuel
130°F
140°F
200°F

 

Downloads

MANUAL
370 Series Vapor Eliminator and Level Controller
PDF Icon
Scroll to Top